Vibration sensor NVT/S3 PLd

PLD
Image may differ
Vibration sensor NVT/S3 PLd
Vibration sensor NVT/S3 PLd
   
Price on request

Prices plus VAT plus shipping costs

Delivery time approx. 60 business days

Product group:

Design:

Housing material:

Number of switching outputs:

Anzahl Frequenzfilter:

Measuring range:

Profile:

Electrical connection:

Number of analogue outputs:

Interface:

Electrical and/or mechanical variant:

Technical customisation

Please enter a value between 1 and 6.

reset

Tragen Sie bitte hier Ihren gewünschten Frequenzfilter zwischen 1 und 6 ein.

Reset configuration
** Required fields
More Options Fewer options

Bestellschlüssel

NVT 90 A 5 0 0 2 S3 M T 01

Would you like more? 9

Cable - 5 - 191 Cable - 5 - 191
Nicht verfügbar
Price on request
Cable - X - 118 Cable - X - 118
Nicht verfügbar
Price on request
Cable - X - 114 Cable - X - 114
Nicht verfügbar
Price on request
Cable - X - 216 Cable - X - 216
Nicht verfügbar
Price on request
Cable - X - 217 Cable - X - 217
Nicht verfügbar
Price on request
Cable - X - 218 Cable - X - 218
Nicht verfügbar
Price on request
Connector STK4GP81 Connector STK4GP81
Nicht verfügbar
Price on request
Connector STK4GP110 Connector STK4GP110
Nicht verfügbar
Price on request
Connector STK4GS60 Connector STK4GS60
Nicht verfügbar
Price on request

Quantity

The sensor system is intended as a component for use e.g. in wind power plants to measure and... more
Product information "Vibration sensor NVT/S3 PLd"

The sensor system is intended as a component for use e.g. in wind power plants to measure and evaluate vibrations in the mast head. Registration of dynamic accelerations by means of MEMS sensors (Micro-Electro-Mechanical System) with subsequent digitisation by a controller.The device consists of an acceleration sensor, a controller unit  and  the  output  interface  PROFIsafe  over  PROFINET  for output of the acceleration values. Thanks to its high resistance to vibration and shock - more than the defined measuring range -, the sensor is suitable for use in areas with rough environmental conditions.Electrical connection is carried out using three connectors. 4 LEDs facilitate commissioning and diagnostics.

Product category: Vibration sensors
Design: 90 mm
Housing material: Aluminium AIMgSi1
Number of frequency ranges: Please specify in the remark field.
Number of switching outputs: 0
Number of analogue outputs: 0
Measuring range: ±2 g
Profile: PROFINET with OPC UA
PROFIsafe to PROFINET - SIL2
Electrical connection: Plug connection with reduced number of connectors
Standard cable connection: 3 cables with length y
Standard plug connection: 3 connectors M12
Interface: PROFIsafe over PROFINET
Electrical and/or mechanical variant: Standard
Certification: PLd
Special feature: PROFINET with OPC UA
9 Dateien verfügbar.
more
Array
(
[15] => Array
(
[name] => Datenblaetter
[files] => Array
(
[en_GB] => Array
(
[0] => Array
(
[id] => 3610
[description] => Data sheet 14587
[filename] => https://www.twk.de/media/pdf/03/49/38/14587fe0.pdf
[size] => 3259148
[attributes] => Array
(
)
)
)
)
)
[17] => Array
(
[name] => Handbücher
[files] => Array
(
[en_GB] => Array
(
[0] => Array
(
[id] => 1864
[description] => Manual 14588
[filename] => https://www.twk.de/media/pdf/c9/6f/0e/14588de0.pdf
[size] => 2511148
[attributes] => Array
(
)
)
)
)
)
[19] => Array
(
[name] => Zertifikate
[files] => Array
(
[en_GB] => Array
(
[0] => Array
(
[id] => 2183
[description] => Certificate PROFINET 15256
[filename] => https://www.twk.de/media/pdf/16/2f/f8/15256ae0.pdf
[size] => 435291
[attributes] => Array
(
)
)
[1] => Array
(
[id] => 2340
[description] => Certificate PROFIsafe 15638
[filename] => https://www.twk.de/media/pdf/9c/d9/71/15638ae0.pdf
[size] => 388797
[attributes] => Array
(
)
)
)
[en_de] => Array
(
[0] => Array
(
[id] => 2129
[description] => Zertifikat PLd 15215
[filename] => https://www.twk.de/media/pdf/be/8e/83/15215ab0.pdf
[size] => 476473
[attributes] => Array
(
)
)
)
)
)
[21] => Array
(
[name] => Step Dateien
[files] => Array
(
)
)
[16] => Array
(
[name] => GSD-ESD-ESI
[files] => Array
(
[en_de] => Array
(
[0] => Array
(
[id] => 3497
[description] => GSD file
[filename] => https://www.twk.de/media/archive/g0/23/0c/GSD-file-NVTS3-T01.zip
[size] => 11879
[attributes] => Array
(
)
)
)
)
)
[18] => Array
(
[name] => Anleitungen
[files] => Array
(
)
)
[20] => Array
(
[name] => Software
[files] => Array
(
)
)
[56] => Array
(
[name] => Technische Dokumentation
[files] => Array
(
)
)
[22] => Array
(
[name] => Sonstige
[files] => Array
(
[en_GB] => Array
(
[0] => Array
(
[description] => UKCA Declaration of Conformity
[filename] => https://twk.de/media/pdf/89/01/24/16569ae0.pdf
)
[1] => Array
(
[id] => 3632
[description] => Kennwertbibliothek (VDMA/Sistema)
[filename] => https://www.twk.de/media/archive/b7/40/ac/VDMA_Safety_Library.zip
[size] => 84464
[attributes] => Array
(
)
)
)
[en_de] => Array
(
[0] => Array
(
[description] => Reach Konform/compliant
[filename] => https://twk.de/media/pdf/97/34/49/15286fb0.pdf
)
[1] => Array
(
[description] => RoHS Konform/compliant
[filename] => https://twk.de/media/pdf/7f/81/9f/13284hb0.pdf
)
)
[globe] => Array
(
[0] => Array
(
[description] => CE Declaration of Conformity
[filename] => https://twk.de/media/pdf/0d/49/0e/12467rx0.pdf
)
)
)
)
)
1
Viewed