Vibration sensor NVA/S3 PLd

Image may differ
Vibration sensor NVA/S3 PLd
Vibration sensor NVA/S3 PLd
Vibration sensor NVA/S3 PLd
     
Price on request

Prices plus VAT plus shipping costs

Delivery time approx. 60 business days

Product group:

Design:

Housing material:

Number of switching outputs:

Anzahl Frequenzfilter:

Measuring range:

Profile:

Electrical connection:

Number of analogue outputs:

Galvanic separation:

Interface:

Electrical and/or mechanical variant:

Technical customisation

Please enter a value between 1 and 6.

reset

Tragen Sie bitte hier Ihren gewünschten Frequenzfilter zwischen 1 und 6 ein.

Reset configuration
** Required fields
More Options Fewer options

Bestellschlüssel

NVA 115 A 1 0 0 2 S3 S3 V1 N 01

Would you like more? 6

Connector STK5WP102 Connector STK5WP102
Nicht verfügbar
Price on request
Connector STK5GS67 Connector STK5GS67
Nicht verfügbar
Price on request
Connector STK5WS87 Connector STK5WS87
Nicht verfügbar
Price on request
Connector STK5GS56 Connector STK5GS56
Nicht verfügbar
Price on request
Connector STK5WS58 Connector STK5WS58
Nicht verfügbar
Price on request
Connector STK5GP90 Connector STK5GP90
Nicht verfügbar
Price on request

Quantity

The sensor system is intended as a component for use e.g. in wind power plants to measure and... more
Product information "Vibration sensor NVA/S3 PLd"

The sensor system is intended as a component for use e.g. in wind power plants to measure and evaluate vibrations in the mast head. Registration of dynamic accelerations by means of MEMS sensors (Micro-Electro-Mechanical System) with subsequent digitisation by a controller. The device consists of an acceleration sensor, a controller unit and three types of output interface. The main feature is two safety switching contacts (potential-free), which can be used e.g. in the safety chain to undertake safety shut-off in the event of excessively high acceleration values. Data output is carried out via the CANopen interface. The standard or the safety profile can be selected. There are additionally two analogue outputs 4 ... 20 mA, which can be optionally assigned to two of the three measurement axes. Thanks to its high resistance to vibration and shock, the sensor is suitable for use in areas with rough environmental conditions. Electrical connection is carried out using two or three connectors.

Product category: Vibration sensors
Design: 115 mm
120 mm
Housing material: Aluminium Druckguss ADC 12
Number of frequency ranges: Please specify in the remark field.
Number of switching outputs: 0
1
2
Number of analogue outputs: Please specify in the remark field.
Profile: Certification in preparation
Certified as per the data in this data sheet
Not certified
Electrical connection: 1x device connector M12, 4/5-pin
2x device connector M12, 4/5-pin
3x device connector M12, 4/5-pin
Galvanic seperation: V1: -UB ǂ CAN_GND ǂ screen/housing (recommended)
V2: -UB = CAN_GND ǂ screen/housing
V3: -UB = CAN_GND = screen/housing
Interface: Analogue
CANopen
CANopen Safety
Relais
Electrical and/or mechanical variant: Standard
Certification: PLd
9 Dateien verfügbar.
more
Array
(
[15] => Array
(
[name] => Datenblaetter
[files] => Array
(
[de_DE] => Array
(
[0] => Array
(
[id] => 157
[description] => Datenblatt 13482
[filename] => https://www.twk.de/media/pdf/1d/59/49/13482ld0.pdf
[size] => 1897041
[attributes] => Array
(
)
)
)
[en_GB] => Array
(
[0] => Array
(
[id] => 158
[description] => Data sheet 13482
[filename] => https://www.twk.de/media/pdf/cb/a4/a8/13482le0.pdf
[size] => 1818189
[attributes] => Array
(
)
)
)
)
)
[17] => Array
(
[name] => Handbücher
[files] => Array
(
)
)
[19] => Array
(
[name] => Zertifikate
[files] => Array
(
[en_de] => Array
(
[0] => Array
(
[id] => 1705
[description] => Certificate PLd 14898
[filename] => https://www.twk.de/media/pdf/84/20/b5/14898ab0.pdf
[size] => 7471843
[attributes] => Array
(
)
)
)
)
)
[21] => Array
(
[name] => Step Dateien
[files] => Array
(
)
)
[16] => Array
(
[name] => GSD-ESD-ESI
[files] => Array
(
)
)
[18] => Array
(
[name] => Anleitungen
[files] => Array
(
)
)
[20] => Array
(
[name] => Software
[files] => Array
(
)
)
[56] => Array
(
[name] => Technische Dokumentation
[files] => Array
(
)
)
[22] => Array
(
[name] => Sonstige
[files] => Array
(
[de_DE] => Array
(
[0] => Array
(
[id] => 1599
[description] => Handbuch 13660
[filename] => https://www.twk.de/media/pdf/77/6d/g0/13660ld0.pdf
[size] => 5718109
[attributes] => Array
(
)
)
)
[en_GB] => Array
(
[0] => Array
(
[description] => UKCA Declaration of Conformity
[filename] => https://twk.de/media/pdf/89/01/24/16569ae0.pdf
)
[1] => Array
(
[id] => 1856
[description] => Manual 13660
[filename] => https://www.twk.de/media/pdf/6a/a2/f7/13660le0.pdf
[size] => 6095548
[attributes] => Array
(
)
)
)
[en_de] => Array
(
[0] => Array
(
[description] => Reach Konform/compliant
[filename] => https://twk.de/media/pdf/97/34/49/15286fb0.pdf
)
[1] => Array
(
[description] => RoHS Konform/compliant
[filename] => https://twk.de/media/pdf/7f/81/9f/13284hb0.pdf
)
)
[globe] => Array
(
[0] => Array
(
[description] => CE Declaration of Conformity
[filename] => https://twk.de/media/pdf/0d/49/0e/12467rx0.pdf
)
)
[z] => Array
(
[0] => Array
(
[id] => 1853
[description] => XML Datei
[filename] => https://www.twk.de/media/archive/a6/9a/18/NVA-S3-13-12-2017.zip
[size] => 3373
[attributes] => Array
(
)
)
)
)
)
)
1
Viewed